The mesh ends up being pretty similar every time, showing that the right side of the bed is lower than the left. The concern is that, when printing after auto leveling, the nozzle is far too close on the right side, causing first layer issues, but all is well on the left. It’s almost like the printer believes that the nozzle is further from the bed than it actually is, but only on one side.
I found that the bolts holding the gantry to the base had come loose slightly, and tightened them. That seemed to help a bit, but the issue is still there. I was going to try leveling the x gantry, but I’m still trying to figure out how to do so.
I did some research and was able to pull the mesh. I put it into a visualizer and found that the right side is definitely incorrect (as it matches with the “too low” behavior that I’m seeing. I tried to copy the image here, but Sync won’t let me, but here’s the values.
0 1 2 3 4 5 6 7 8 9 10 11 12
0 +0.03500 -0.02855 -0.09156 -0.15566 -0.22250 -0.29867 -0.38125 -0.45758 -0.51500 -0.54590 -0.55844 -0.56363 -0.57250
1 +0.01869 -0.01856 -0.05355 -0.09305 -0.14383 -0.21602 -0.30324 -0.38746 -0.45064 -0.48415 -0.49888 -0.50610 -0.51707
2 +0.00234 -0.00695 -0.01215 -0.02553 -0.05938 -0.12765 -0.22023 -0.31329 -0.38297 -0.41951 -0.43676 -0.44629 -0.45969
3 -0.01393 +0.00144 +0.02248 +0.03217 +0.01352 -0.05072 -0.14723 -0.24723 -0.32193 -0.36066 -0.37977 -0.39103 -0.40621
4 -0.03000 +0.00178 +0.04016 +0.06533 +0.05750 -0.00240 -0.09922 -0.20143 -0.27750 -0.31633 -0.33563 -0.34711 -0.36250
5 -0.04428 -0.00747 +0.03596 +0.06615 +0.06324 +0.00837 -0.08337 -0.18082 -0.25285 -0.28864 -0.30564 -0.31512 -0.32836
6 -0.05734 -0.02364 +0.01604 +0.04376 +0.04156 -0.00781 -0.09062 -0.17835 -0.24250 -0.27303 -0.28596 -0.29184 -0.30125
7 -0.07236 -0.04528 -0.01310 +0.00888 +0.00535 -0.03877 -0.11166 -0.18823 -0.24340 -0.26810 -0.27650 -0.27838 -0.28352
8 -0.09250 -0.07094 -0.04500 -0.02781 -0.03250 -0.07238 -0.13719 -0.20465 -0.25250 -0.27246 -0.27719 -0.27582 -0.27750
9 -0.11980 -0.10205 -0.08041 -0.06654 -0.07207 -0.10913 -0.16849 -0.22982 -0.27275 -0.28955 -0.29183 -0.28831 -0.28770
10 -0.15219 -0.13878 -0.12196 -0.11197 -0.11906 -0.15424 -0.20929 -0.26559 -0.30453 -0.31884 -0.31920 -0.31399 -0.31156
11 -0.18660 -0.17777 -0.16597 -0.16010 -0.16902 -0.20270 -0.25387 -0.30559 -0.34092 -0.35300 -0.35165 -0.34493 -0.34090
12 -0.22000 -0.21563 -0.20875 -0.20688 -0.21750 -0.24949 -0.29656 -0.34348 -0.37500 -0.38473 -0.38156 -0.37324 -0.36750
The bed leveling is done with the bed and nozzle preheated to printing temp. As for the probe, it’s the stock probe on the Ender 3 Max Neo.
The interesting part is the heat soak. I typically heat it and then only wait a minute or two. I’ll let it sit for a while and try again.
How do you edit, or even view, the map that’s built?
Kriega makes great bags! I use a US-20 Drybag from them and absolutely love it. Easy to put on and take off of my KLR and I’d trust it to keep anything dry. It’s also easy to move around to other bikes, especially if you get an extra set of straps.
Beautiful bike. I’ve got a '14 STR in white and red and I love it. I don’t think I’ll ever sell it.